Referenze

Structural strengthening with Carbon FRCM for the Thurgood Marshall Federal Courthouse din New York

FRCM Carbon System in unusual, highly complex application

The FRCM structural strengthening system with carbon fibre, was selected for an unusual and highly complex application in New York, providing an effective, functional solution, thanks to its ability to meet technical-performance requirements combined with ease of application and durability. The FRCM system selected for this job was C-Mesh 84/84, consisting of a bi-directional carbon mesh (84+84 g/m2) combined with MX-C 25 Masonry inorganic matrix, and C-JOINT carbon fibre connectors.

Structural strengthening of the masonry in the lift shafts

When it was inaugurated, in 1936, the Thurgood Marshall Federal Courthouse was the tallest public building in the United States.   In 2021, the building, consisting of a 33 storey tower, was the subject of large-scale renovation, work being carried out on the granite facades and the striking golden pyramidal roof, as well as the various fire prevention and safety systems, the entrances, stairways and lift shafts.   The latter presented evidence of deterioration attributable to the effects of water infiltration and vibration. Due to the unusual context in which the work needed to be carried out, coupled with the need limit the length of time the systems would be out of service, the works management opted for a solution that involved strengthening the masonry structures of the lift shafts based on Ruregold’s FRCM composite material solutions.   Given the specific nature of this application, it was decided to adopt C-Mesh 84/84, consisting of the bi-directional carbon fibre mesh (84+84 g/m2) and the MX-C 25 Masonry inorganic matrix, together with C-JOINT Carbon fibre connector. C-JOINT is the carbon fibre anchoring element used to connect masonry and reinforced concrete structures. The fibre connector is prepared on site and consists of a bundle of continuous parallel fibres or strands bound within a tubular elastic net made of polyester, polyamide and latex fibres. The mesh can be extended both longitudinally and transversely, and may also be removed.   The bundle only becomes rigid once it has been impregnated with the specific inorganic matrix MX-JOINT, and inserted into the respective holes that have been pre-drilled on the structural element. The system is used for applications on masonry, such as wrapping or shear and flexural strengthening and, thanks to the high grammage of the carbon fibre mesh and the high performance of the organic matrix, it can be used to increase the capacity of structural elements to resist in and out of plane actions as well as the ductility of masonry buildings, guaranteeing high reliability thanks to its post-cracking response under detachment conditions.   Resistant to freeze-thaw cycles and high temperatures, the C-Mesh 84/84 system may also be applied on damp supports without the need for special protections. The ease of use and reliability of the inorganic matrix, which is laid using the same techniques as cementitious mortar, represent advantages that are unique to FRCM structural strengthening systems.

Per quale motivo ci vuoi contattare?

    Consenso al trattamento dei dati personali:*

    I campi contrassegnati con l’asterisco (*) sono obbligatori

    Iscriviti alla newsletter

    Rimani aggiornato sulle novità, le soluzioni e i prodotti del mondo Laterlite S.p.A.

      Consenso al trattamento dei dati personali:*

      I campi contrassegnati con l’asterisco (*) sono obbligatori

      How can we help you?

      Error: Contact form not found.

      Subscribe to our newsletter

      Stay up to date on news, solutions and products from the world of Laterlite S.p.A.

      Error: Contact form not found.

      How can we help you?

      Error: Contact form not found.

      How can we help you?

      Error: Contact form not found.

      How can we help you?

      Error: Contact form not found.

      This site is registered on wpml.org as a development site.